OverviewThis report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 DegreesC (500 DegreesF) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved. Full Product DetailsAuthor: NistPublisher: Createspace Independent Publishing Platform Imprint: Createspace Independent Publishing Platform Dimensions: Width: 21.60cm , Height: 0.50cm , Length: 28.00cm Weight: 0.231kg ISBN: 9781496136602ISBN 10: 1496136608 Pages: 90 Publication Date: 07 March 2014 Audience: General/trade , General Format: Paperback Publisher's Status: Active Availability: Available To Order ![]() We have confirmation that this item is in stock with the supplier. It will be ordered in for you and dispatched immediately. Table of ContentsReviewsAuthor InformationTab Content 6Author Website:Countries AvailableAll regions |