|
![]() |
|||
|
||||
OverviewRadiosurgery performed with a ""Gamma Knife"" or on a linac facility is a specific radiotherapy method to treat certain lesions in the brain with a high single radiation dose. Geometric miss of a radiosurgica target is considered the most likely serious error in a steroetactic radiosurgery treatment. Quality assurance in this field, therefore, is of the utmost importance. This book is designed to offer and describe a quality assurance programme. It identifies the sources of possible errors and suggests quality assurance tests that should be performed in order for a stereotactic system to be used clinically. Full Product DetailsAuthor: Gunter Hartmann , W. Lutz , J. Arndt , I. ErmakovPublisher: Springer-Verlag Berlin and Heidelberg GmbH & Co. KG Imprint: Springer-Verlag Berlin and Heidelberg GmbH & Co. K Edition: Softcover reprint of the original 1st ed. 1995 Weight: 0.130kg ISBN: 9783540591993ISBN 10: 3540591990 Pages: 93 Publication Date: 01 July 1995 Audience: Professional and scholarly , Professional & Vocational Format: Paperback Publisher's Status: Active Availability: In Print ![]() This item will be ordered in for you from one of our suppliers. Upon receipt, we will promptly dispatch it out to you. For in store availability, please contact us. Table of Contents1 Introduction.- 1.1 Purpose of the Report.- 1.2 Definition of Key Terms.- 1.2.1 Accuracy and Precision.- 1.2.2 The Isocenter Concept.- 1.2.3 Target Point.- 1.2.4 Volumes.- 2 Quality Assurance Aspects and Requirements.- 2.1 Quality Assurance Aspects of Stereotactic Target Localization.- 2.1.1 Background.- 2.1.2 Key Parameters and Requirements.- 2.1.2.1 First Parameter.- 2.1.2.2 Second Parameter.- 2.1.2.3 Third Parameter.- 2.2 Quality Assurance Aspects of Dosimetry and Treatment Planning.- 2.2.1 Background.- 2.2.1.1 Dosimetry.- 2.2.1.2 Treatment Planning.- 2.2.2 Key Parameters and Requirements.- 2.3 Quality Assurance Aspects in Treatment Delivery.- 2.3.1 Background.- 2.3.1.1 Gamma Knife Radiosurgery.- 2.3.1.2 Linac-Based Radiosurgery.- 2.3.2 Key Parameters and Requirements.- 3 Description of Recommended Quality Assurance Tests.- 3.1 Stereotactic Localization and Immobilization.- 3.1.1 Major Quality Assurance Issues.- 3.1.2 Tests.- 3.2 Dosimetry and Treatment Planning.- 3.2.1 Major Quality Assurance Issues.- 3.2.2 Tests.- 3.3 Treatment Delivery.- 3.3.1 Major Quality Assurance Issues.- 3.3.2 Tests.- 3.3.2.1 Tests for Gamma Knife (Model B) Based Radiosurgery.- 3.3.2.2 Tests for Linac-Based Radiosurgery.- 3.3.2.3 Method Independent Treatment Delivery Tests.- 4 List of Tests.- 4.1 Stereotactic Localization and Immobilization.- 4.2 Dosimetry and Treatment Planning.- 4.3 Treatment Delivery.- 4.3.1 Tests for Gamma Knife (Model B) Based Radiosurgery.- 4.3.2 Tests for Linac-Based Radiosurgery.- 4.3.3 Method Independent Treatment Delivery Tests.- Appendix A. Accuracy Requirements for Dosimetry from Tumor Control Probability Data.- Appendix B. Suggestion for Testing a Treatment Planning System.- Appendix C. Correction of Spatial Distortion in Magnetic Resonance Imaging for Stereotactic Operation/Treatment Planning in the Brain.- References.ReviewsAuthor InformationTab Content 6Author Website:Countries AvailableAll regions |