Introduction to Power System Protection

Author:   Dr Hidaia Mahmood Alassouli
Publisher:   Blurb
ISBN:  

9798211894259


Pages:   154
Publication Date:   07 April 2024
Format:   Paperback
Availability:   In stock   Availability explained
We have confirmation that this item is in stock with the supplier. It will be ordered in for you and dispatched immediately.

Our Price $62.04 Quantity:  
Add to Cart

Share |

Introduction to Power System Protection


Add your own review!

Overview

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.

Full Product Details

Author:   Dr Hidaia Mahmood Alassouli
Publisher:   Blurb
Imprint:   Blurb
Dimensions:   Width: 20.30cm , Height: 0.80cm , Length: 25.40cm
Weight:   0.318kg
ISBN:  

9798211894259


Pages:   154
Publication Date:   07 April 2024
Audience:   General/trade ,  General
Format:   Paperback
Publisher's Status:   Active
Availability:   In stock   Availability explained
We have confirmation that this item is in stock with the supplier. It will be ordered in for you and dispatched immediately.

Table of Contents

Reviews

Author Information

Tab Content 6

Author Website:  

Customer Reviews

Recent Reviews

No review item found!

Add your own review!

Countries Available

All regions
Latest Reading Guide

wl

Shopping Cart
Your cart is empty
Shopping cart
Mailing List