Biomarkers for Assessing and Managing Iron Deficiency Anemia in Late-Stage Chronic Kidney Disease: Future Research Needs: Future Research Needs Paper Number 33

Author:   Agency for Healthcare Resea And Quality ,  U S Department of Heal Human Services
Publisher:   Createspace Independent Publishing Platform
ISBN:  

9781490527857


Pages:   52
Publication Date:   24 June 2013
Format:   Paperback
Availability:   Available To Order   Availability explained
We have confirmation that this item is in stock with the supplier. It will be ordered in for you and dispatched immediately.

Our Price $39.57 Quantity:  
Add to Cart

Share |

Biomarkers for Assessing and Managing Iron Deficiency Anemia in Late-Stage Chronic Kidney Disease: Future Research Needs: Future Research Needs Paper Number 33


Add your own review!

Overview

Anemia is a common complication of chronic kidney disease (CKD). The management of anemia in CKD patients must strike an appropriate balance between stimulating generation of erythroblasts (erythropoiesis) and maintaining sufficient iron levels for optimum hemoglobin (Hb) production. As such, it is important to assess iron stores and the availability of iron for erythropoiesis, as adequate iron status is integral to both iron and anemia managements in CKD patients. Classical iron status tests, of which ferritin and transferrin saturation (TSAT) are the most widely used, exhibit large biological variability in the context of underlying inflammation of CKD. The accurate assessment of iron status is dependent on the validity and reliability of laboratory test results, and differences in test performance pose a dilemma regarding the most appropriate test to guide treatment decisions. Several novel biomarkers of iron status have been proposed as alternatives to the classical iron status tests. These include hemoglobin content of reticulocytes (CHr), reticulocyte hemoglobin equivalent (RetHe), percentage of hypochromic erythrocytes (%HYPO), erythrocyte zinc protoporphyrin (ZPP), soluble transferrin receptor (sTfR), and hepcidin. In addition, Superconducting Quantum Interference Devices (SQUIDs) are an alternative non-invasive means for detecting and quantifying liver iron content, via the paramagnetic properties of iron (magnetic resonance diminishes in the liver as iron concentration increases). The Tufts Evidence-based Practice Center (EPC) conducted a Comparative Effectiveness Review (CER) to systematically evaluate studies that examined the impact on patient-centered outcomes of using the newer laboratory biomarkers as a replacement for or as an add-on to classical laboratory biomarkers of iron status for assessing iron status and the management of iron deficiency in adult and pediatric CKD patients (nondialysis and dialysis). The Key Questions for the CER are presented below: Key Question 1 (Overarching Question) What is the impact on patient centered outcomes of using the newer laboratory biomarkers as a replacement for or an add-on to the older (classical) laboratory biomarkers of iron status for assessing iron status and management of iron deficiency in stages 3-5 CKD patients (nondialysis and dialysis), and in patients with a kidney transplant? Key Question 2 What is the test performance of newer markers of iron status as a replacement for or an addon to the older markers in stages 3-5 CKD patients nondialysis and dialysis, and in patients with a kidney transplant? a. What reference standards are used for the diagnosis of iron status in studies evaluating test performance? b. What are the adverse effects or harms associated with testing using newer and/or older markers of iron status? Key Question 3 In stages 3-5 nondialysis and dialysis CKD patients with iron deficiency, what is the impact of managing iron status based on newer laboratory biomarkers either alone or in addition to older laboratory biomarkers on intermediate outcomes (e.g., improvement in Hb levels, dose of erythropoiesis-stimulating agents, time in target Hb range), compared with managing iron status based on older laboratory biomarkers alone? a. What are the adverse effects or harms associated with the treatments guided by tests of iron status? Key Question 4 What factors affect the test performance and clinical utility of newer markers of iron status, either alone or in addition to older laboratory biomarkers, in stages 3-5 (nondialysis and dialysis) CKD patients with iron deficiency?

Full Product Details

Author:   Agency for Healthcare Resea And Quality ,  U S Department of Heal Human Services
Publisher:   Createspace Independent Publishing Platform
Imprint:   Createspace Independent Publishing Platform
Dimensions:   Width: 21.60cm , Height: 0.30cm , Length: 28.00cm
Weight:   0.145kg
ISBN:  

9781490527857


ISBN 10:   1490527850
Pages:   52
Publication Date:   24 June 2013
Audience:   General/trade ,  General
Format:   Paperback
Publisher's Status:   Active
Availability:   Available To Order   Availability explained
We have confirmation that this item is in stock with the supplier. It will be ordered in for you and dispatched immediately.

Table of Contents

Reviews

Author Information

Tab Content 6

Author Website:  

Customer Reviews

Recent Reviews

No review item found!

Add your own review!

Countries Available

All regions
Latest Reading Guide

MRG2025CC

 

Shopping Cart
Your cart is empty
Shopping cart
Mailing List